Wednesday, 13 June 2012

OVERLOAD ALARM WARNING SYSTEM IN A PASSENGER LIFT WITH NUMBER OF OCCUPANTS INDICATION


Model no.19A: 
           This application keeps the database of the number of persons entering the lift as well as exiting. 555 timer driven 38 KHz signal from IR LED gets interrupted on to the IR receiver to sense the person entering as well as exiting which is fed to a 555 timer. The output of 555 timer is fed to the Microcontroller for analyzing and control purpose. The data obtained from microcontroller is given to the 7-segment display unit which displays the number of persons entering, and exiting the lift. This project includes TSOP 1738 IR sensor for detecting purpose. A relay is used to control the warning signal through its ‘NO’ contacts, it is interfaced with microcontroller through a relay driver. The power supply consists of a step down transformer 230/12V, which steps down the voltage to 12V AC. This is converted to DC using a Bridge rectifier. The ripples are removed using a capacitive filter and it is then regulated to +5V using a voltage regulator 7805 which is required for the operation of the microcontroller and other components.

For more details about this project, please visit     http://www.efxkits.com/project-kit/microcontroller/1070.html


HARDWARE REQUIREMENTS:

Microcontroller unit, 7-segment display unit, Diodes, Voltage Regulator, Capacitors, Resistors, BC547, LED, Push button, IR LED’s, IR sensor, 555 Timer, Relay, load.

SOFTWARE REQUIREMENTS:

Keil compiler, Languages: Embedded C or Assembly